Automatic Line to Battery transfer

● Rack / Tower design, installation versatility

● Adjustable wider input voltage range and charging current

● Intelligent charging control, efficient charging

● Auto restart when mains power is restored

● Superior protection: low battery, overcharge, overload, overtemperature and short circuit

● High load-bearing capacity, supporting various household loads and IT equipment (< 50% half-wave load, < 30% inductive load)

MODEL 1200 VA 1500 VA 2400 VA
Capacity 720 W 900 W 1440 W
INPUT
Rated voltage 220 / 230 / 240 Vac (selectable)
Voltage range 220 / 230 / 240 Vac, -22% / -59% ~ +26%, ± 5 Vac (selectable)
Rated frequency 50 / 60 Hz (auto-sensing)
Frequency range

± 10% (default), ± 5% ~ 15% (selectable)

OUTPUT
Power factor 0.6
Output voltage

Battery mode: 220 / 230 / 240 Vac ± 10% (selectable)

Mains mode: synchronized with utility power

Output frequency

 

Battery mode: 50 / 60 Hz ± 1% (selectable);

Mains mode: synchronized with utility power
Output waveform

Battery mode: square wave;

Mains mode: synchronized with utility power
Inversion efficiency ≥ 83% (max.) ≥ 85% (max.)
≥ 83% (max.) Yes
Half-wave load ≤ 50% (rated load)
Inductive load ≤ 30% (rated load)
BATTERIES
Rated voltage 12 Vdc 24 Vdc
Charging current (Max.)

20 / 10 A ± 3 A (selectable)

15 / 10 A ± 3 A (selectable)

Equalizing charge voltage Single battery 14.2 ± 0.3 Vdc (default), 13.6 ~ 15.0 Vdc (selectable)
Floating charge voltage Single battery 13.6 ± 0.3 Vdc
Low voltage alarm Single battery 10.8 ± 0.3 Vdc (default), 9.6 ~ 13.0 Vdc (selectable)
Low voltage shutdown

Single battery 10.2 ± 0.3 Vdc (default), 9.6 ~ 12.0 Vdc (selectable)

Overvoltage protection Single battery 15.0 ± 0.3 Vdc
Overvoltage recovery Single battery 13.6 ± 0.3 Vdc
SYSTEM
Transfer time ≤ 8 ms (typical) , ≤ 15 ms (max.)
Protections Overload, short circuit, over-temperature, output over/under-voltage, excessive low battery

Overload times (Mains mode)

≥ 110% for 120 s, ≥ 125% for 60 s, ≥ 150% for 10 s, ≥ 200% for 1 s

Overload times (Battery mode) ≥ 110% for 60 s, ≥ 125% for 5 s, ≥ 150% for 1 s
Communication interface No
Panel display LCD + LED
OTHERS
Operating temperature 0 ~ 45℃
Operating humidity 0 ~ 95% (no-condensing)
Altitude ≤ 1000 m (Above 1000 m, derating 1% for each additional 100 m)
IP rating IP 20
Cooling Forced-air cooling
Noise < 45 dB
Dimensions (W x D x H) (mm) 245 x 220 x 80
Packaged dimensions (W x D x H) (mm) 315 x 290 x 156
Net weight (kg) 2.66 2.68 2.82
Gross weight (kg) 3.02 3.04 3.18

                Note: "Selectable" can be customized according to customer requirements.