APOLLO GROUP CO., LTD.

AP900 Pro RT 1 – 3 kVA

Characteristics Technical Specifications Documents

● High frequency on-line double conversion technology

● DSP (Digital signal processors) control technology

● Active power factor correction (APFC), input power factor up to 0.99

● Output power factor 0.9

● Wide input voltage range (110 V ~ 300 Vac) and frequency range (40 ~ 70 Hz)

● Auto sensing frequency

● 50 / 60Hz frequency conversion

● Cold start

● Rear ventilation design and variable speed fan

● Effective software and hardware protection

● Quick and stable charging, 90% capacity restored in 4 h (standard model UPS)

● Linear derating in low voltage input reducing battery discharging times

● Settable delayed start when power is restored

● Hot-swappable battery

● Advanced battery management (ABM)

● Multiple functions settable via LCD: output voltage, EOD, auto-start, bypass mode, ECO mode and frequency conversion mode

● Multi-platform communications: RS232 (standard), USB / RS485 / SNMP / dry contacts (optional)

● Optional USB, RS485 card, AS400 dry contacts, SNMP card, SMS alarms, EPO function, MBS (External maintenance bypass switch)

AP901RT-AP903RT (1 - 3 kVA)
MODEL AP901RT (H) AP902RT (H) AP903RT (H)
Capacity 1 kVA / 900 W 2 kVA / 1800 W 3 kVA / 2700 W
INPUT
Rated voltage 208 /   220 / 230 / 240 Vac
Voltage range 110 ~ 176 Vac (linear derating between 50% and 100% load); 176 ~ 280 Vac (no   derating); 280 ~ 300 Vac (derating 50%)
Frequency 40 ~ 70 Hz (auto-sensing)
Power factor ≥ 0.99
Bypass voltage   range - 25% ~ + 15% settable
Total harmonic distortion ≤ 6%
OUTPUT
Voltage 208 / 220 / 230 / 240 Vac   (settable via LCD)
Voltage regulation ± 1%
Frequency 45 ~ 55 Hz or 55 ~ 65 Hz (synchronized range); 50 / 60 Hz ± 0.1 Hz (battery mode)
Waveform Sinusoidal
Power factor 0.9
Total harmonic distortion (THDv) ≤ 2% (linear load), ≤ 5% (non-linear load)
Crest factor 3:1
Overload 105% ~ 125% for 1 min, 125% ~ 150% for 30 s, > 150% for 300 ms
BATTERIES
DC voltage 24 V 36 V 36 V (H) 48 V  72 V  72 V (H) 72 V 96 V (H)
Inbuilt battery  2 x 9 Ah 3 x 7 Ah / 4 × 9 Ah 6 x 7 Ah / 6 × 9 Ah /
Charging current (max.) 1A 6 A 1 A 6 A 1 A 6 A
Recharge time Standard model: 90% capacity restored in 3 hours;
    Long time model: depend on the capacity of battery    
SYSTEM
Efficiency ≥ 90% (Mains mode)
    ≥ 85% (Battery mode)
    ≥ 95% (ECO mode)  
≥ 91% (Mains mode)
    ≥ 86% (Battery mode)
    ≥ 96% (ECO mode)    
≥ 92% (Mains mode)

 ≥ 87% (Battery mode)

 ≥ 97% (ECO mode)

Transfer time Mains mode to battery mode: 0 ms
    Inverter mode to bypass mode: 4 ms (typical)
Protections Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection
Communications RS232 (standard), USB / RS485 / dry contacts / SNMP (optional)
Display LCD + LED
Standards EN   62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC   61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC   61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 62040-1    
OTHERS
Operating   temperature 0℃ ~ 40℃
Storage temperature - 25 ~ 55°C (without   batteries)
Relative humidity 0 ~ 95% (non-condensing)
Altitude ≤ 1000 m, derating 1% for each additional 100 m
IP rating IP 20
Noise level at 1m ≤ 50 dB 
Dimensions
(W × D × H) (mm)
440 x 338 x 88 440 x 430 x 88 440 x 468 x 88 440 x 430 x 88 440 x 560 x 88 440 x 468 x 88 440 x 560 x 88 440 x 468 x 88
Packaged dimensions
(W × D × H) (mm)
545 x 428 x 194 545 x 560 x 201 545 x 592 x 201 545 x 560 x 201 545 x 690 x 201 545 x 592 x 201 545 x 690 x 201 545 x 592 x 201
Net weight (kg) 10.6 15.5 7.6 18.7 25.6 9.7 26.8 10.1
Gross weight (kg) 11.3 18.6 11.1 21.8 25.8 13.2 29.7 13.6

AP900 RT 1 kVA ~ 3 kVA Datasheet -  PDF